11. The seven-step design procedure

Figure 1. The torsion design procedure.
Figure 1. The torsion design procedure.

Step 1 — Establish the load and its eccentricity

  • Locate the point of load application on the section.
  • Locate the shear center — for a Channel it lies outside the web.
  • Compute the eccentricity e, then T = P × e (concentrated) or t = w × e (distributed).

Step 2 — Screening check: is a torsion analysis needed at all?

T_r / T_c ≤ 0.20   →   torsion may be neglected  (AISC 360 §H3.1)

Quick estimate of T_c:
  Open section  : T_c = φ · 0.6 · F_y · J / t_max
  Closed section: T_c = φ · 0.6 · F_y · C   (C from the AISC Manual)

Steps 3 to 5 — Properties, load case, derivatives

PropertySourceNote
J, CwAISC Manual — Dimensions & PropertiesAll sections
W_noDG9 Appendix A — Table A.1W-shape: at the flange tip
S_wDG9 Appendix A — Table A.1At the point being checked
Q_f, Q_wDG9 Appendix A — Table A.1W-shape flange and web

Compute a = √(E·Cw / G·J) and λ = L/a, pick the Case from the 12 in DG9, then evaluate four quantities at the critical location.

  • θ — angle of twist, used for the serviceability check.
  • θ' — gives the St. Venant shear stress τ_t.
  • θ'' — gives the warping normal stress σ_w.
  • θ''' — gives the warping shear stress τ_w.

Step 6 — Compute the three torsional stresses

τ_t = G · t · θ'              use the THICKEST element
σ_w = E · W_no · θ''          governs at the outer flange tip
τ_w = E · S_w · θ''' / t      usually at the flange–web junction

12. Combining stresses and checking to AISC 360

The total stress at a point is the algebraic sum of every component acting at that same point.

Total normal stress:  f_n = f_bx + f_by + σ_w + f_a
Total shear stress :  f_v = f_vx + f_vy + τ_t + τ_w

f_bx, f_by = major- and minor-axis bending   f_a  = axial
f_vx, f_vy = shear on each axis
CheckFormulaφ (LRFD)
Normal stressf_n ≤ φ · F_y0.90
Shear stressf_v ≤ φ · 0.6·F_y1.00
Von Mises√(f_n² + 3·f_v²) ≤ φ · F_y0.90

Closed sections (HSS) — the H3-6 interaction equation

( P_r/P_c + M_rx/M_cx + M_ry/M_cy ) + ( V_r/V_c + T_r/T_c )² ≤ 1.0

Take the LARGER of the two axes for V_r/V_c.

Nominal torsional strength:  T_n = F_cr · C
  Rectangular HSS:  C ≈ 2·(B−t)·(H−t)·t
  Round HSS      :  C = π·(D−t)²·t / 2
Ratio h/tLimit stateF_cr
h/t ≤ 2.45·√(E/F_y)Yielding0.6·F_y
2.45·√(E/F_y) < h/t ≤ 3.07·√(E/F_y)Inelastic buckling0.6·F_y · 2.45·√(E/F_y) / (h/t)
h/t > 3.07·√(E/F_y)Elastic buckling0.458·π²·E / (h/t)²

Open sections — check several points

AISC 360 gives no simple interaction equation for open sections. Compute the total stress and compare with the capacity point by point — at least four points on the section.

PointNormal stressShear stress
A — top flange tipf_bx + σ_wτ_t (small)
B — flange–web junctionf_bxτ_t + τ_w + f_vy
C — mid-web0f_vy + τ_t
D — bottom flange tipf_bx ∓ σ_wτ_t

13. Formulas for the common loading cases

Case 1 — Pinned–Pinned, concentrated T at midspan

The most common case in practice. Boundary conditions: θ = 0 and θ'' = 0 at both ends.

For 0 ≤ z ≤ L/2:

  θ(z)    = T/(G·J) · [ z/2 − (a/2)·sinh(z/a)/cosh(L/2a) ]
  θ'(z)   = T/(2·G·J) · [ 1 − cosh(z/a)/cosh(L/2a) ]
  θ''(z)  = −T/(2·G·J·a) · sinh(z/a)/cosh(L/2a)
  θ'''(z) = −T/(2·G·J·a²) · cosh(z/a)/cosh(L/2a)

Extreme values at midspan:
  θ_max  = T/(2·G·J) · [ L/2 − a·tanh(L/2a) ]
  θ'_max = T/(2·G·J) · [ 1 − 1/cosh(L/2a) ]

Case 3 — Pinned–Pinned, uniform t over the full span

This is the spandrel beam carrying a wall load.

θ'(z)   = t/(G·J) · [ (L−2z)/2 + a·sinh((L−2z)/2a)/cosh(L/2a) ]
θ''(z)  = t/(G·J) · [ −1 + cosh((L−2z)/2a)/cosh(L/2a) ]
θ'''(z) = t/(G·J·a) · sinh((L−2z)/2a)/cosh(L/2a)

Case 9 — Fixed–Free (cantilever), T at the free end

θ'(z)   =  T/(G·J) · [ 1 − cosh((L−z)/a)/cosh(L/a) ]
θ''(z)  =  T/(G·J·a) · sinh((L−z)/a)/cosh(L/a)
θ'''(z) = −T/(G·J·a²) · cosh((L−z)/a)/cosh(L/a)

Extremes:  θ and θ' peak at z = L (free end)
           θ'' and θ''' peak at z = 0 (fixed support)

14. Worked example 1 — W-shape under an eccentric load

Member        : W16×26  (A992, F_y = 50 ksi)
Span          : L = 20 ft = 240 in
Load          : P = 10 kips at midspan, eccentricity e = 6 in
End conditions: Pinned–Pinned (free warping both ends)

Design torque: T = P × e = 10 × 6 = 60 kip-in → use Case 1.

PropertyW16×26Unit
J0.262in⁴
C_w456in⁶
W_no15.5in²
S_w5.35in⁴
t_f / t_w0.345 / 0.250in
a = √( 29,000 × 456 / (11,200 × 0.262) ) = √4,507 = 67.1 in
L/a = 240 / 67.1 = 3.58
L/2a = 1.789     cosh(1.789) = 3.121     tanh(1.789) = 0.946

θ_max = 60/(2 × 11,200 × 0.262) × [ 120 − 67.1 × 0.946 ]
      = 0.01022 × 56.5 = 0.578 rad

Try a heavier section: W16×50

W16×50:  J = 1.52 in⁴    C_w = 2,340 in⁶

a = √( 29,000 × 2,340 / (11,200 × 1.52) ) = √3,986 = 63.1 in
L/2a = 1.902     tanh(1.902) = 0.956

θ_max = 60/(2 × 11,200 × 1.52) × [ 120 − 63.1 × 0.956 ]
      = 0.001762 × 59.7 = 0.105 rad  ≈ 6°

15. Worked example 2 — HSS, a far simpler route

Member  : HSS 8×6×3/8  (A500 Gr.C, F_y = 50 ksi)
Span    : L = 20 ft
Load    : P = 10 kips at midspan, eccentricity e = 6 in
Also    : M_x = 50 kip-ft, V = 10 kips

T_r = P × e = 60 kip-in
h/t = 20.0    versus    2.45·√(E/F_y) = 2.45·√(29,000/50) = 59.0
→ 20.0 is below 59.0  →  limit state: YIELDING

F_cr = 0.6 × 50 = 30 ksi
T_n  = F_cr × C = 30 × 72.7 = 2,181 kip-in
T_c  = φ × T_n = 0.90 × 2,181 = 1,963 kip-in   (LRFD)

T_r / T_c = 60 / 1,963 = 0.031  ≤  0.20   →  TORSION NEGLECTED

For reference: running H3-6 anyway

M_rx = 600 kip-in     M_cx = 0.90 × 50 × 21.3 = 958.5 kip-in
V_r  = 10 kips        V_c  ≈ 150.8 kips

( 0 + 600/958.5 + 0 ) + ( 10/150.8 + 60/1,963 )²
= 0.626 + (0.066 + 0.031)² = 0.626 + 0.0094 = 0.635  ≤  1.0   ✓

16. AISC versus Eurocode (SCI P385)

AspectAISC (DG9)Eurocode (SCI P385)
Base codeAISC 360, DG9EN 1993-1-1
Resistance factorsφ = 0.90 (bending), 1.00 (shear)γ_M0 = γ_M1 = 1.00
Warping torsionDirect σ_w, τ_wVia the bimoment B
Closed sectionsEquation H3-6τ_t,Ed / (f_y/√3) ≤ 1.0

The bimoment concept in SCI P385

B   = E · C_w · θ''            (bimoment)
σ_w = B · W_no / C_w

Bending–torsion interaction (simplified, open sections):
  M_y,Ed / M_y,Rd + σ_w,Ed / (f_y/γ_M0) ≤ 1.0

17. Design strategy and six traps

Priority order when torsion appears

  • 1. Eliminate it — put the load through the shear center, add lateral bracing, detail connections so reactions pass through the shear center. Always the best option.
  • 2. Minimise it — cut the eccentricity, add bracing points, use a composite slab (the concrete restrains warping of the top flange).
  • 3. Switch to HSS — if torsion is significant and unavoidable. The calculation is far simpler because warping drops out.
  • 4. Full open-section analysis — only when a W-shape or Channel is mandatory.

Six traps that catch engineers out

TrapWhy it bites
1. Ignoring a Channel's shear centerIt lies outside the web — a load through the centroid still twists it.
2. Confusing torsional and warping restraintA clip angle restrains twist but not warping. When unsure, assume Pinned.
3. Forgetting the twist checkChecking stress but not θ. Excessive twist causes vibration and damages cladding and glazing.
4. Missing the DG9 errataEarly printings contain formula, chart and Case-label errors. Always check the current errata.
5. Taking frame-software torque at face valueT from SAP2000/STAAD excludes warping — it is St. Venant only. You must compute σ_w and τ_w yourself.
6. Combining stresses at different pointsBending peaks at the flange, warping at the flange tip, shear in the web — you may not add extremes from different locations.

Which W-shape if you must use one?

  • Wide, thick flanges raise both J and Cw — clearly better.
  • A thick web raises J.
  • Greater depth raises Cw but lowers J — a trade-off.
  • Prefer wide-flange series (W14, W12); avoid slender sections such as W24×55 or W21×44 — their J is tiny.

18. Torsion design checklist

  • Does the load pass through the shear center? If so, there is no torsion.
  • Compute T = P × e using a correctly located shear center.
  • Check T_r/T_c ≤ 0.20 — if satisfied, stop; torsion is negligible.
  • Choose the section type: HSS if torsion is significant.
  • Look up J, Cw, W_no, S_w from the AISC Manual and DG9 Appendix A.
  • Compute a = √(E·Cw / G·J) and L/a.
  • Determine the end conditions: Fixed, Pinned or Free.
  • Select the load Case from the 12 in DG9 Appendix B.
  • Evaluate θ, θ', θ'', θ''' at the critical location.
  • Compute τ_t, σ_w and τ_w.
  • Combine f_n and f_v at no fewer than four points on the section.
  • Check f_n ≤ φ·F_y and f_v ≤ φ·0.6·F_y.
  • Check the twist θ against the serviceability limit.
  • For HSS: check equation H3-6 ≤ 1.0.

19. Quick reference tables

MATERIAL CONSTANTS (steel)
  E = 29,000 ksi = 200,000 MPa
  G = 11,200 ksi =  77,200 MPa
  ν = 0.30

LRFD LIMITS
  Normal stress : f_n ≤ 0.90 · F_y
  Shear stress  : f_v ≤ 1.00 · 0.6·F_y
  Von Mises     : √(f_n² + 3f_v²) ≤ 0.90 · F_y

J, Cw and a for common W-shapes

SectionJ (in⁴)Cw (in⁶)W_no (in²)a (in)
W8×310.53621212.232.0
W10×491.3962016.534.0
W12×501.711,88025.053.3
W14×481.452,24027.263.2
W14×904.064,99033.056.4
W16×260.26245615.567.1
W16×501.522,34023.663.1
W21×440.7702,11024.584.2
W24×551.183,87029.192.0

Channels and HSS

SectionJ (in⁴)Cw (in⁶) / C (in³)Note
C10×15.30.20954.8e₀ = 0.634 in
C15×33.90.904349e₀ = 0.788 in
HSS 8×6×3/886.2C = 72.7Common
HSS 12×8×1/2353C = 265Very strong

20. Seven key recommendations

  • Try to detail the torsion away before you start calculating.
  • If torsion is significant, use a closed section (HSS) — simpler and far more effective.
  • Locate the shear center precisely, especially for Channels.
  • Get the end conditions right — Fixed versus Pinned changes the answer dramatically.
  • Always check the twist θ alongside the stresses.
  • Combine stresses at the same point — never add extremes from different locations.
  • Check the DG9 errata before trusting any formula.

Part of the “Industrial structural design guide” series by Roberto Structural. The content is technical guidance only; the engineer remains responsible for verifying and adapting it to each project and the governing code. Codes change — always check the current edition, including the AISC Design Guide 9 errata.